Evaluación y propuesta de optimización del sistema de tratamiento de agua potable en la zona urbana del municipio de Toca
Trabajo de grado - Pregrado
2023-11-14
Universidad de Boyacá
Tratamiento del agua -Toca (Boyacá, Colombia) - Investigaciones
Plantas de Tratamiento de Agua -Toca (Boyacá, Colombia) - Investigaciones
Calidad del agua - Tesis y disertaciones académicas
Abastecimiento de agua - Toca (Boyacá, Colombia) - Investigaciones
Contaminación del agua - Toca (Boyacá, Colombia) - Investigaciones
Saneamiento Ambiental - Toca (Boyacá, Colombia) - Investigaciones
Agua potable
Diagnostico
Optimización
PTAP
Diseños
Drinking water
Diagnosis
Optimization
Designs
Plantas de Tratamiento de Agua -Toca (Boyacá, Colombia) - Investigaciones
Calidad del agua - Tesis y disertaciones académicas
Abastecimiento de agua - Toca (Boyacá, Colombia) - Investigaciones
Contaminación del agua - Toca (Boyacá, Colombia) - Investigaciones
Saneamiento Ambiental - Toca (Boyacá, Colombia) - Investigaciones
Agua potable
Diagnostico
Optimización
PTAP
Diseños
Drinking water
Diagnosis
Optimization
Designs
El presente estudio surge del análisis de los resultados del índice de riesgo para la calidad de agua potable en los últimos años obtenidos del Sistema de Información de la Vigilancia de la Calidad del Agua para Consumo Humano, en el cual se evidencia una distribución de agua no apta para consumo humano por los niveles de riesgo obtenidos en la mayoría de las muestras, esta problemática de calidad implico a realizar diagnóstico de la calidad de agua de la fuente abastecedora y el sistema de tratamiento actual del municipio de Toca, mediante tomas de muestras en afluente y efluente para realizar análisis fisicoquímicos y microbiológicos con el fin de identificar los factores de riesgo asociados a la PTAP y generar alternativas de optimización y selección de sistema de tratamiento.
El sistema de tratamiento de agua potable de la zona urbana del municipio de Toca se evaluó mediante la información histórica recopilada, resultados de análisis de calidad del agua bajo la resolución 2115 del 2007, proyecciones de caudal y la evaluación de las dimensiones establecidas en la resolución 0330 del 2017, de lo que se obtuvo que el caudal actual con el que opera la planta es menor al que se requiere para el otro año mediante proyección aritmética y a su vez se evidencio que el sedimentador de la planta convencional no cumple con el tiempo de retención hidráulica establecidos en normativa según sus medidas, por lo cual se define que hay que implementar una alternativa que aumente la capacidad de la planta.
El enfoque metodológico es de carácter mixto, considerando que se realizó una recolección de datos o variables que explican la calidad del agua en la planta de agua potable del municipio de Toca, de igual forma, se considera investigación aplicada ya que pretende dar solución a una problemática social actual que aqueja a la comunidad que se beneficia del servicio de acueducto. Para la recolección de información primaria se realizaron visitas de campo y trabajo de laboratorio para recopilar información diagnostica y documentación existente de la Unidad de Servicios Públicos. De igual forma, para la recolección de información secundaria se realizó una revisión literaria a través de libros, EOT municipal, planos, manuales, mapas, entre otros.
De forma general, se recomienda al Municipio de Toca, implementar a corto plazo en el Sistema Convencional Tipo Compacto una filtración convencional independiente del sistema FIME: con la intención de aumentar la capacidad del caudal en todo el sistema y suplir con la demanda de la población, logrando abastecer hasta el año 2042. También se establece que a largo plazo se debe aumentar el tratamiento del sistema incluyendo procesos que remuevan los parámetros problemas en el efluente que son: nitritos, hierro, manganeso, color aparente y turbiedad con el fin de cumplir con la resolución 2115 del 2007. (tomado del texto) The present study arises from the analysis of the results of the risk index for the quality of drinking water in recent years obtained from the Information System of the Surveillance of the Quality of Water for Human Consumption, in which a distribution of water unfit for human consumption is evidenced by the risk levels obtained in most of the samples, This quality problem led to a diagnosis of the water quality of the supplying source and the current treatment system of the municipality of Toca, by taking samples of influent and effluent for physicochemical and microbiological analysis in order to identify the risk factors associated with the PTAP and generate alternatives for optimization and selection of the treatment system.
The drinking water treatment system of the urban area of the municipality of Toca was evaluated through historical information collected, results of water quality analysis under resolution 2115 of 2007, flow projections and evaluation of the dimensions established in resolution 0330 of 2017, from which it was obtained that the current flow with which the plant operates is less than what is required for the other year by arithmetic projection and in turn it was evidenced that the sedimenter of the conventional plant does not comply with the hydraulic retention time established in regulations according to its measurements, so it is defined that an alternative to increase the capacity of the plant must be implemented.
The methodological approach is of a mixed nature, considering that a collection of data or variables that explain the quality of the water in the drinking water plant of the municipality of Toca was carried out, likewise, it is considered applied research since it aims to provide a solution to a current social problem that afflicts the community that benefits from the aqueduct service. For the collection of primary information, field visits and laboratory work were carried out to compile diagnostic information and existing documentation of the Public Services Unit. Similarly, for the collection of secondary information, a literature review was carried out through books, municipal EOT, plans, manuals, maps, among others.
In general, it is recommended to the Municipality of Toca to implement in the short term a conventional filtration system independent of the FIME system in the Compact Type Conventional System: with the intention of increasing the flow capacity throughout the system and supplying the population's demand, achieving supply until the year 2042. It is also established that in the long term the treatment of the system should be increased including processes that remove the problem parameters in the effluent which are: nitrites, iron, manganese, apparent color and turbidity in order to comply with resolution 2115 of 2007. (tomado del texto)
Descripción:
Evaluación y propuesta de optimización del sistema de tratamiento de agua potable en la zona urbana _removed.pdf
Título: Evaluación y propuesta de optimización del sistema de tratamiento de agua potable en la zona urbana _removed.pdf
Tamaño: 3.859Mb
PDFLEER EN FLIP
Descripción: Carta de autorización moreno rodriguez.pdf
Título: Carta de autorización moreno rodriguez.pdf
Tamaño: 207.4Kb
PDF
Descripción: Formato entrega trabajos de grado Deyler y Camila.pdf
Título: Formato entrega trabajos de grado Deyler y Camila.pdf
Tamaño: 214.6Kb
PDF
Descripción: Nota de aceptación Deyler y Camila..pdf
Título: Nota de aceptación Deyler y Camila..pdf
Tamaño: 62.06Kb
PDF
Título: Evaluación y propuesta de optimización del sistema de tratamiento de agua potable en la zona urbana _removed.pdf
Tamaño: 3.859Mb
PDFLEER EN FLIP
Descripción: Carta de autorización moreno rodriguez.pdf
Título: Carta de autorización moreno rodriguez.pdf
Tamaño: 207.4Kb
Descripción: Formato entrega trabajos de grado Deyler y Camila.pdf
Título: Formato entrega trabajos de grado Deyler y Camila.pdf
Tamaño: 214.6Kb
Descripción: Nota de aceptación Deyler y Camila..pdf
Título: Nota de aceptación Deyler y Camila..pdf
Tamaño: 62.06Kb